Spécifications techniques
Paramètres | Spécifications |
---|---|
Nom du produit | Aiguille à biopsie 10G-22G, 3.4mm-0.7mm |
Matériau - Canule | Medical-grade SUS304 stainless steel; hardened and polished for durability |
Gamme de jauges | 10G - 22G |
Diamètre extérieur (OD) | 3,4 mm (10G) - 0,7 mm (22G) |
Options de longueur | 100 mm – 250 mm (±1 mm tolerance); customizable per procedure |
Conception de l'embout | Tri-beveled, ultra-sharp for skin penetration; core-cutting type |
Depth Markings | Clear tick marks in 1 cm increments for controlled puncture depth |
Outer Cannula Tail | Flared and frosted for better grip and stability |
Inner Needle Core Tail | Flattened for easy identification and manipulation |
Hub Type | Standard Luer-lock / custom ergonomic handle |
Finition de la surface | Mirror-polished cannula, reduces friction during insertion |
Méthode de stérilisation | Ethylene Oxide (EO) or Gamma sterilized |
Emballage | Individually sterile blister packs, 10 pcs per box |
Usage unique | Oui |
Certifications | ISO 13485, CE marking, FDA approval (regional availability) |
Durée de conservation | 3-5 ans dans des conditions de stockage contrôlées |
Biopsy Needle: Precision Tissue Sampling for Definitive Diagnosis.
Biopsy Needle Clinical Purpose
Our biopsy needle delivers unparalleled accuracy in obtaining high-yield tissue cores for pathological analysis. Designed for ultrasound, CT, or MRI-guided procedures, it enables reliable sampling of lesions in organs including liver, breast, prostate, and lung—critical for cancer diagnosis, staging, and treatment planning.
Principaux avantages
Optimal Sample Integrity
– Twin-bevel cutting edge: Ultra-sharp 14° tip preserves tissue architecture with minimal crushing artifact.
– Adjustable throw length (10–25mm): Customizable penetration depth for precise lesion targeting.
Enhanced Safety & Control
– Echogenic distal notch: Real-time ultrasound visibility with 360° rotational alignment.
– One-handed firing mechanism: Smooth trigger operation reduces hand tremor risks.
Efficacité de la procédure
– Core sample retrieval >98% success rate (per Radiology 2024 study data).
– Integrated vacuum assist maintains sample cohesion during withdrawal.
Ingénierie des matériaux avancés
– Cannula: Electropolished 304VM stainless steel (wall thickness: 0.13mm) for superior flexural strength.
– Trocar: Tungsten-carbide reinforced tip (HRC 62±2) retains sharpness through dense tissue.
– Coating: Hydrophilic polymer (contact angle: 12°) reduces insertion force by 50%.
Applications
– Core needle biopsy (CNB) of tumors
– Breast biopsy under stereotactic guidance
– Transrectal prostate sampling
– Lung nodule FNA/FNB procedures