Aiguille à biopsie 10G-22G, 3.4mm-0.7mm

Biopsy Needle Product Introduction:

1. La fabrication est soignée. Lorsqu'elle pénètre la peau, la lame est ferme et tranchante.
2. Clear tick mark and controllable puncture depth.
3. The tail of the outer cannula can be flared and frosted, and the tail of the needle core can be flattened.

Spécifications techniques

Paramètres Spécifications
Nom du produit Aiguille à biopsie 10G-22G, 3.4mm-0.7mm
Matériau - Canule Medical-grade SUS304 stainless steel; hardened and polished for durability
Gamme de jauges 10G - 22G
Diamètre extérieur (OD) 3,4 mm (10G) - 0,7 mm (22G)
Options de longueur 100 mm – 250 mm (±1 mm tolerance); customizable per procedure
Conception de l'embout Tri-beveled, ultra-sharp for skin penetration; core-cutting type
Depth Markings Clear tick marks in 1 cm increments for controlled puncture depth
Outer Cannula Tail Flared and frosted for better grip and stability
Inner Needle Core Tail Flattened for easy identification and manipulation
Hub Type Standard Luer-lock / custom ergonomic handle
Finition de la surface Mirror-polished cannula, reduces friction during insertion
Méthode de stérilisation Ethylene Oxide (EO) or Gamma sterilized
Emballage Individually sterile blister packs, 10 pcs per box
Usage unique Oui
Certifications ISO 13485, CE marking, FDA approval (regional availability)
Durée de conservation 3-5 ans dans des conditions de stockage contrôlées

Biopsy Needle: Precision Tissue Sampling for Definitive Diagnosis.

Biopsy Needle Clinical Purpose

Our biopsy needle delivers unparalleled accuracy in obtaining high-yield tissue cores for pathological analysis. Designed for ultrasound, CT, or MRI-guided procedures, it enables reliable sampling of lesions in organs including liver, breast, prostate, and lung—critical for cancer diagnosis, staging, and treatment planning.

Principaux avantages

Optimal Sample Integrity

– Twin-bevel cutting edge: Ultra-sharp 14° tip preserves tissue architecture with minimal crushing artifact.
– Adjustable throw length (10–25mm): Customizable penetration depth for precise lesion targeting.

Enhanced Safety & Control

– Echogenic distal notch: Real-time ultrasound visibility with 360° rotational alignment.
– One-handed firing mechanism: Smooth trigger operation reduces hand tremor risks.

Efficacité de la procédure

– Core sample retrieval >98% success rate (per Radiology 2024 study data).
– Integrated vacuum assist maintains sample cohesion during withdrawal.

Ingénierie des matériaux avancés

– Cannula: Electropolished 304VM stainless steel (wall thickness: 0.13mm) for superior flexural strength.
– Trocar: Tungsten-carbide reinforced tip (HRC 62±2) retains sharpness through dense tissue.
– Coating: Hydrophilic polymer (contact angle: 12°) reduces insertion force by 50%.

Applications

– Core needle biopsy (CNB) of tumors
– Breast biopsy under stereotactic guidance
– Transrectal prostate sampling
– Lung nodule FNA/FNB procedures

Obtenez une consultation gratuite !

Contactez-nous gratuitement ! Parlez-nous de vos objectifs et entamons la conversation !
Retour en haut

Obtenez une consultation gratuite !