Manual Single Channel Pipette, Pipette Supplier

Manual Single Channel Pipette, Pipette Supplier

The manual single channel pipette is ergonomically designed, with a wider range of adjustable volumes and high precision. It is impact-resistant, UV-resistant and chemical corrosion-resistant. The tip components are made of specific materials, which can be disassembled for high-temperature and high-pressure sterilization, and support independent volume calibration.

SPECIFICATIONS

Technical Parameters

Product Description:

– Automation Level: Manual Pipette
– Instrument Type: Single-channel Pipette
– Application Fields: Medical and health care, chemical industry, biological industry, pharmaceutical/biopharmaceutical, comprehensive field

Technical Parameter:

model Specification Increment Measuring point Maximum allowable error Maximum allowable error
Inaccuracy Inaccuracy
μL % %
0.1~2.5μL 0.1~2.5μL 0.05μL 1.25μL ±3.00% 3.00%
0.25μL ±12.00% 6.00%
0.5~10μL 0.5~10μL 0.1μL 10μL ±1.00% 0.80%
5μL ±1.50% 1.50%
1μL ±2.50% 1.50%
2~20μL 2~20μL 0.5μL 20μL ±0.90% 0.40%
10μL ±1.20% 1.00%
2μL ±3.00% 2.00%
5~50μL 5~50μL 0.5μL 50μL ±0.60% 0.30%
25μL ±0.90% 0.60%
5μL ±2.00% 2.00%
10~100μL 10~100μL 1.0μL 100μL ±0.80% 0.20%
50μL ±1.00% 0.40%
10μL ±3.00% 1.00%
20~200μL 20~200μL 1.0μL 200μL ±0.60% 0.20%
100μL ±0.80% 0.30%
20μL ±2.50% 0.80%
100~1000μL 100~1000μL 5.0μL 1000μL ±0.60% 0.20%
500μL ±0.70% 0.25%
100μL ±2.00% 0.70%
1000~5000μL 1000~5000μL 50.0μL 5000μL ±0.50% 0.20%
2500μL ±0.60% 0.30%
1000μL ±0.70% 0.30%
1~10ml 1~10ml 100μL 10000μL ±0.60% 0.20%
5000μL ±1.20% 0.30%
1000μL ±3.00% 0.60%
Manual single channel pipette 0.1-2.5ul
Manual single-channel pipette (0.1 – 2.5μl)
single channel pipette 0.5-10ul
single-channel pipette (0.5 – 10μl)
single channel pipette 1-5ml
single-channel pipette (1-5ml)
single channel pipette 1-10ml
single-channel pipette (1-10ml)
Manual single channel pipette 2-20ul
single channel pipette 2-20μl
Manual single channel pipette 5-50ul
single-channel pipette (5-50μl)
Manual single channel pipette 10-100ul
single-channel pipette (10-100μl)
Manual single channel pipette 20-200ul
single-channel pipette (20-200μl)
Manual single channel pipette 100-1000ul
single-channel pipette (100-1000μl)

The lockable volume controller reduces the number of rotations by 50%. During manual operation, the relevant display is visible.

FEATURES

Customization Advantages

Precision engineering for complex medical applications

Geometry Expertise

J-hooks, helical coils, side ports, multi-lumen structures, or patient-specific bends. Micro-barb retention elements, fluid channels (≥50μm ID), or directional drug delivery windows.

Advanced Manufacturing

Laser micromachining precision ±5μm. Electroforming for seamless tapered transitions. Nitinol shape-memory integration for steerable functionality.

Rapid Prototyping

Surgical-grade steel / PEEK 3D-printed prototypes delivered within 72 hours. CFD and structural simulation reports to accelerate product validation.

Ready to Discuss Your Custom Requirements?

Our application engineering team is ready to provide expert support at every step.

FAQs

Q: What is a single channel pipette?

A: Manual single-channel pipettes are single-channel laboratory devices used in conjunction with disposable pipette tips to exactly transfer measured quantities of liquids. Products include repeating pipettes and positive-displacement products.

Q: What are manual pipettes?

A: Single Channel, Multichannel, and Adjustable Spacer Multichannel Mechanical Pipettes. A manual pipette is a handheld instrument used in life science laboratories to accurately measure and dispense microvolumes of liquids between multi-well plates, microtubes, and reservoirs.

Q: What is a single channel pipette also known as?

A: A single-channel pipette, also referred to as a single-channel micropipette, is used to aspirate and dispense a measured amount of liquid. As it contains a single channel, it can transfer one aliquot at a time and is therefore mostly used for low-throughput laboratory applications.

Q: How to calibrate a manual pipette?

A: Steps Involved in the Calibration of Your Pipette: Place a weigh boat on a balance that can accurately weigh in the microgram range, and set it to zero after closing the balance door. Pre-rinse the tip by aspirating and dispensing the set volume three times, and push it fully to remove any remaining liquid.